The Evolution of Indoor Environmental Quality

Part 1: Best Practices for Good IAQ

Part 2: IEQ Factors Daylighting, Thermal Comfort and Acoustics for Healthy Space


Best Practices for Good IAQ

By Lacey Muszynski, Associate Editor - August 2010 - IAQ


No one has to tell a facility manager that the consequences of poor indoor air quality (IAQ) can go from bad — complaints about headaches and allergies — to worse, with increased absences and even sick building syndrome. Creating a healthy space for building occupants is one pillar of the sustainability movement. There's good reason for that: When occupants are healthy, they're also usually happy and productive, which translates directly to an organization's bottom line.

Recently, the definition of what creates a healthy space for human beings has been expanding. IAQ has evolved beyond looking only at air quality, in part because many good IAQ steps have become standard practice. "The issues related to preventing bad air are much easier to accomplish," says Rico Cedro, president of Verdi Workshop. "We're at a point where we can achieve good IAQ just by doing best practices and complying with ASHRAE standards."

Indoor environmental quality (IEQ) is the next generation of IAQ. It includes looking at issues such as daylighting, thermal comfort and acoustics. Facility managers who understand the role a healthy space plays in supporting productivity and an organization's mission would be wise to examine a building's IEQ.

IAQ Best Practices

Even if a facility manager is interested in IEQ, the importance of good IAQ cannot be understated. IAQ has a direct effect on the health and well-being of a facility's occupants. Lawrence Berkeley National Laboratories (LBNL) has performed myriad studies on the effects of IAQ and found that worker productivity goes down, student test scores suffer and health problems occur when in a facility with poor IAQ. For example, a pair of studies showed that office worker performance, measured by typing, addition and proofreading tests, improved by about 4 percent when an indoor pollutant source was removed.

"High levels of certain chemicals in the air can also lead to respiratory problems, nosebleeds, allergic reactions, headaches and dizziness," says Henning Bloech, executive director of the Greenguard Environmental Institute.

To maintain good IAQ, there are some guidelines a facility manager can follow. First, it's important to keep up on HVAC maintenance. HVAC systems play an important role in ensuring good IAQ, but can fail to do so if not properly maintained. Be sure to change filters, clean coils and replace any worn parts on a timely basis. Always inspect for equipment damage, failure or malfunction to keep everything working smoothly.

Second, avoid bringing in materials and products that off-gas VOCs or other potentially problematic chemicals or odors. "That new product smell? Ultimately what you're smelling is off-gassing from the product," says Bloech. Look for interior products and materials that carry an independent, third-party green certification for IAQ. Some of the largest certifications include Greenguard and Green Seal for many types of products, FloorScore for resilient and hard surface flooring, and Green Label and Green Label Plus for carpeting. Without a third-party certification, be cautious of green claims made by manufacturers that are not backed by facts.

If it's necessary to bring a non-green or strong-smelling product into a facility while occupied, such as an adhesive or solvent, facility managers should be sure to seal off the area where the work is being performed, including sealing HVAC vents, says Bloech. But in most cases, there are low-emitting alternatives available, he says. "Compared to 10 years ago, low-emitting paints and adhesives perform much better now and many manufacturers have them."

Finally, implement a green cleaning program. Bringing in unhealthy cleaning chemicals on a regular basis can contaminate otherwise healthy spaces and defeat the purpose of carefully choosing green interior products. VOCs in cleaning products have been shown to be significant respiratory irritants in studies by LBNL and EPA, among others. In one study, a high frequency of use of standard cleaning chemicals was associated with a 40 percent increase in wheezing, a 50 percent increase in asthma symptoms or medication use, and a 100 percent increase in physician-diagnosed asthma. Even worker's compensation authorities noticed a pattern of high rates of adult-onset asthma in health care workers because those facilities are cleaned while occupied, says Guenther.

Like other interior products, cleaning products and even cleaning programs can be certified by third-party sustainability labels. Different labels tend to focus on different aspects of sustainability. For example, some labels focus on the chemical composition and how it will affect the water supply once it is discarded. Not all labels require IAQ performance testing, so be sure that contractors use products certified by labels such as Greenguard.

Comments

Larry Morgan wrote re: Best Practices for Good IAQ
on 10/4/2010 12:26:21 PM

You can implement all the new techniques on the market but if there are no baselines to compare IAQ against your not creating the proper value add to the overall program. I suggest contracting with a registered industrial hygenist that can provide this service and going forward on an annual basis random sampling program., If you can't measure it you can't manage it.

Bob Croft wrote re: Best Practices for Good IAQ
on 8/26/2010 6:20:54 PM

Quite a lot you can achieve using simple janitorial procedures. Here's a note I posted a bit ago:

Haven't Owned a Dust Mop in Years
Think for a moment on the efficiency of the common dust mop. In open areas, particles roll under the dust-mop and remain on the floor, and small particles become airborne in the flow of air over the mop, remain in the air for hours, and settle back to earth unless inhaled by an opportunistic passer-by. Corners and edges are missed (dirt piles up in the corners, day by day). Areas around and under furniture are bypassed entirely. And dust is a biggie hereabouts - we're a janitiorial service in Phoenix, AZ.

The remedy is to replace the dust-mop with a back pack vacuum.

A standard rule of thumb in the industry holds that, when damp-mopping (should one be thorough enough to dump the mop water when it becomes dirty), one should plan to dump the mop water twice as often if you dust-mopped, rather than vacuumed, before hand.

The above applies to VCT (vinyl) floors. Imagine the additional effect of texture and grout lines in rough stone and ceramic floors. Most all dirt stays on the floor, to be turned to mud when the damp-mop hits.

Hard to argue that the janitor with his dust-mop is simply trying to keep costs down for his client. Although a decent back pack vacuum (with hard-floor nozzle) costs a good deal more than the dust mop (check any janitorial supply firm), its greater efficiency saves much more in labor costs over the months. Further, the more dust particles one removes from the building tonight, by vacuuming the floor, the fewer particles need to be dusted off surfaces tomorrow. Saves time, and labor costs, both nights.

Finally, a HEPA filter on the vacuum, followed by damp-mopping with a microfiber mop (to pull up any particles missed by the vacuum) gives one clean, unstreaked floors and improved indoor air quality. Hard to find a dust mop with a HEPA filter.

A bit about us:

My firm, CBN Building Maintenance, provides commercial cleaning services in Phoenix AZ and the wider metro area. We've been in business since 1974; hold the BBB's A-plus rating; and have long been in the forefront of the industry in environmentally sensitive cleaning for health, safety and security. Our program can generally improve Indoor Air Quality, in the size range of most allergens, by a factor of 50%, as reflected in our ongoing IAQ sampling.

Mvinick wrote re: Best Practices for Good IAQ
on 8/19/2010 3:16:32 PM

With all due respect IAQ is a lot more complex than this article depicts. Perhaps there is poor pitch in a drain pan that has created standing water and it can be repaired. Or internal insulation is deteriorating and should be either coated or ripped out and replaced. The ductwork may be dirty and needs to be cleaned. The system may even need to be balanced every few years for optimal air flow. These are just a few possible things to look at besides simply following ASHREA guidelines which I agree are a terrific starting point. Thank you. Michael Vinick President Duct & Vent Cleaning of America, Inc


Add a comment

Next




The Evolution of Indoor Environmental Quality

Part 1: Best Practices for Good IAQ

Part 2: IEQ Factors Daylighting, Thermal Comfort and Acoustics for Healthy Space



RELATED

Browse articles on iaq, ieq, hvac, mold, vocs, green cleaning on FacilitiesNet

FACILITYZONE SEARCH

Search for iaq, ieq, hvac, mold, vocs, green cleaning articles on FacilityZone


Modine. Save Thousands of Dollars in Energy & Thousands of Pounds in CO2. Click here.



VDF-induced bearing currents kill motors! Shaft Grounding Rings protect bearings/motors from electrical damage. Click here to learn more about AEGIS.


*************************

Free E-mail Newsletter Sign-up

Weekly Articles
Facility Webcast Alerts
Building Products/Technology
Monthly Digital Magazine


1 + 3  = (anti-spam)

*************************
*************************
*************************